The gap between timber decking boards is small, but it affects drainage, cleaning and how the deck copes as the wood gains and loses moisture. Here is a practical UK guide to board spacing, including the details at walls, posts and board ends.

Quick answer: For most adjacent timber decking boards, leave a consistent 5–8 mm gap. That is the Timber Decking and Cladding Association (TDCA) recommendation and matches GripDeck’s general advice. Check the exact board supplier’s instructions before installation: species, board width and moisture content can change the detail, and composite decking follows its own manufacturer-specific rules.
Gaps between GripDeck anti-slip softwood decking boards
GripDeck anti-slip softwood boards. Check the gap between boards as you install them.

Why do decking boards need a gap?

Timber is not a fixed-size material. Its moisture content changes through the seasons, and the boards can expand or contract across their width. A gap gives that movement room while allowing rainwater and small debris to leave the walking surface.

1

Drainage

Open joints let water pass through rather than remain trapped between board edges. The deck still needs a suitable fall and a route for water to escape below.

2

Timber movement

Spacing helps accommodate seasonal changes in board width. Boards installed tightly together can close up further when they take on moisture.

3

Inspection and cleaning

Visible, accessible joints make it easier to spot and remove leaves and dirt that hold moisture against the timber.

A board gap cannot compensate for a poorly designed substructure. Air must also circulate around and beneath the deck, and the ground or base below must drain. For the full build sequence, see our UK decking guide.

How much gap should you leave between timber decking boards?

The table is a starting guide for timber decking, not a universal instruction for every board. Confirm the finished board dimensions and any product-specific installation requirements before fixing the first row.

LocationGeneral timber-decking guidanceWhy it matters
Between adjacent board sides 5–8 mm for most timber boards.Drainage, cleaning access and seasonal movement.
Board end meeting a postLeave approximately 5 mm, subject to the board detail.Prevents the board end being forced tightly against the post.
Board beside a building or wallAllow approximately 10 mm at the adjoining structure, subject to the project design.Keeps drainage and airflow available at the edge.
Two board ends over a supported jointDo not force the ends tightly together; follow the timber and installation specification.Both ends need support and secure fixing, with allowance for movement.
Composite deckingUse the specific composite manufacturer’s side and end-gap instructions.Thermal movement and fixing systems differ from timber.

The side-gap and edge figures above follow TDCA timber-decking specification guidance. The size of the surface gap is separate from joist spacing: one is the space between board edges; the other is the distance between supports beneath the boards.

Does the gap change if decking boards are wet or dry?

Yes, the timber’s condition at installation matters. A wet board may shrink as it dries, making the finished gap larger. A drier board may expand when it takes up moisture outdoors. Timber species and board width also affect how much movement to expect.

Do not use a rule such as “fit wet boards tight because they will shrink”. A tight joint may restrict drainage from day one, and no one can guarantee exactly how evenly every board will dry. Likewise, an excessively wide initial gap can leave an awkward finished surface after shrinkage.

Check the pack before laying

Keep boards stored off the ground and protected in line with the supplier’s instructions. Check for unusually wet, uneven or distorted boards before fixing. TDCA advises checking timber moisture content before installation and, where boards are too wet, allowing them to acclimatise in a sheltered position off the ground. Ask the board supplier for the correct spacing when the pack condition is uncertain.

Some hardwoods move less than typical softwood and may have a different specified gap. Thermally modified timber also has its own product guidance. Follow the instructions for the actual board rather than copying a gap used on another project.

How do you keep decking-board gaps consistent?

1

Plan the layout

Measure the finished deck width and the actual board width. Include the chosen gap, perimeter clearances and likely cuts before fixing the first board. Our decking calculator gives an initial board estimate, but final quantities depend on the layout.

2

Use a spacer

Use a suitable spacer at several points along each board. Check the gap at both ends and over intermediate joists; timber edges are not always perfectly straight.

3

Check alignment

Stand back after the first few rows. A small error repeated across many boards can leave a tapered final row or an uneven edge.

4

Fix without closing the joint

Support and fasten each board according to its fixing instructions. Do not pull a bowed board into place so aggressively that the planned gaps disappear.

For a long or irregular deck, work from a measured layout line rather than assuming the building wall is straight. If you are laying boards diagonally, check the increased cutting allowance and the support arrangement in our joist-spacing guide.

What about gaps at walls, posts and board ends?

Perimeter joints are easy to overlook. Do not run a decking board hard against a wall, door threshold or post. At a building, the deck detail must avoid trapping moisture and must preserve the intended ventilation and drainage. TDCA’s general timber-decking guidance gives a 10 mm allowance where boards meet a building and 5 mm where a board end meets a post; the actual construction detail may need more consideration.

Where two board ends meet, provide proper support for both ends. A butt joint should sit over a suitable joist arrangement or additional support, with fixings positioned according to the board and fixing guidance. Do not leave an unsupported end simply to maintain a neat-looking joint. The TDCA’s Timber Decking Handbook illustrates this detail.

Raised or public-access decks: Board gaps are only one part of a safe design. The supporting structure, loading, drainage and edge details must be specified for the project. This article does not provide structural span calculations.

Five common decking-spacing mistakes

  1. Butting boards tightly together. This can restrict water drainage and leave little room for movement.
  2. Using one spacer without checking the whole board. Bowed or tapered boards can produce a gap that changes along the row.
  3. Ignoring the board’s moisture condition. Very wet boards may dry to a much wider finished joint.
  4. Forgetting the perimeter. Boards tight against posts or walls can trap moisture or interfere with movement.
  5. Applying timber guidance to composite. Composite boards and concealed-fixing systems need their own manufacturer’s gap instructions.

Another common mix-up is treating board gaps and joist centres as the same measurement. They solve different problems. Check both before ordering materials.

Do anti-slip timber decking boards need a different gap?

Factory-applied anti-slip inserts do not remove the need to space the timber boards correctly. GripDeck® boards still need drainage, ventilation and allowance for timber movement. The insert sits within the board surface; it does not replace the joint between neighbouring boards.

Choose the gap for the timber species, board section and site conditions, and follow the supplied installation detail. GripDeck’s softwood anti-slip decking, hardwood decking and ThermoDeck® are different materials; one spacing decision should not be assumed to cover all three.

If your question is which face of a grooved board should be upwards, read our separate guide to laying grooved decking the right way up. The visible groove profile and the gap between boards are different details.

Timber decking board-gap FAQs

Is 5 mm enough between decking boards?

Five millimetres is the lower end of TDCA’s general 5–8 mm guidance for adjacent timber boards. Check the exact board, moisture condition and installation instructions before settling on a gap.

Should I leave a gap if the timber is wet?

Yes. Do not assume wet boards can be laid tightly together. Check whether the pack is suitable for installation and follow supplier guidance for its moisture condition.

Can decking-board gaps be too wide?

Yes. An overly wide joint can look uneven and may be unsuitable for the deck’s users. Plan the initial gap with expected timber movement and the product instructions in mind.

Is the gap between boards the same as joist spacing?

No. The board gap is measured between the edges of neighbouring deck boards. Joist spacing is measured centre to centre between supports beneath the boards.

Do hardwood decking boards need the same gap as softwood?

Not always. Movement varies by species and board condition. TDCA notes that some small-movement hardwoods can be installed closer than its general timber guidance; confirm the detail for the supplied product.

How much gap should I leave with composite decking?

Follow the instructions for the exact composite board and fixing system. Timber-decking gap guidance should not be transferred to composite products.

Planning a Timber Deck?

Tell GripDeck® the board type, dimensions, layout and site conditions. We can help you choose suitable anti-slip timber decking and point you to the relevant product guidance before you order.

Discuss Your Project
Scroll to Top